American Institute of Inspectors®
Standards of Practice & Code of Ethics |
CONTENTS DIRECTORY -
(Click on the desired topic)
1.0 INTRODUCTION
The American Institute of Inspectors®;,
Inc., or A.I.I.™ is a NOT- FOR-PROFIT ASSOCIATION of individuals who themselves
perform inspections of residential, industrial, and commercial properties, and
prepare written reports on their condition and who have met the requirement for
membership as determined by the Board of Directors.
This association was formed in order:
A. TO build awareness and
professionalism in the home inspector.
B. TO promote excellence within the
profession and to improve the inspection industry through the A.I.I.™Philosophy of business expressed through the Association's Standards of
Practice, Code of Ethics, and other mutual benefit criteria.
C. TO provide members and others with a
forum in which to enhance their professionalism through education, an
informed exchange of ideas, and other related benefits which can be provided
best by an international association.
D. TO interact with related
professions, the legal community and government bodies as a leading
authority in the home and building inspection profession.
These Standards, and the accompanying Code of
Ethics, are the minimum mandatory standards to which a member shall be held in
order to maintain membership in the association.
CODE of ETHICS
The PHILOSOPHY required for success in the
inspection industry is embodied in our Code of Ethics to which all members
subscribe.
- 1.1 Members SHALL discharge
their duties with fidelity to the public, their clients, and with fairness
and impartiality to all.
-
- 1.2
Every effort SHALL be made to avoid a conflict of interest. The
member shall have absolutely no vested interest in the outcome of the
report. The inspection may not be used as a vehicle to deliberately obtain
additional work in another field.
-
- 1.3
A.I.I.™ Certified Inspectors shall NOT overly scrutinize the
property. The purpose of an A.I.I.™ Certified Inspection is to objectively
state the conditions of the property so that the buyer can validate the
purchase decision.
-
- 1.4
An A.I.I.™ Certified Member's inspection SHALL address the
"Durability" and "Serviceability" of the components of a
property as outlined in the A.I.I.™ Report Forms; and shall NOT be
used to determine the "Desirability" or value of a property.
-
- 1.5
All members agree to submit to binding arbitration any disputes concerning
the practice of their profession.
-
- 1.6
A member will NOT disclose any information concerning the results of
the inspection without the approval of the client. A member shall NOT
accept compensation from more than one interested party for the same
service.
-
- 1.7 A
member shall NOT accept nor offer commissions or allowances, directly
or indirectly, from other parties to induce referrals or reciprocity in the
practice of their business.
-
- 1.8
Members SHALL always advertise and seek business according to the
A.I.I.™ Advertising Guidelines.
-
- 1.9
A member SHALL execute work in conformity with federal, state, and
local laws, maintain all necessary licenses and qualifications, and refuse
to be a party any action that violates these regulations.
-
- 1.10 Members
SHALL make every effort to uphold, maintain, and improve the
professional integrity, reputation and practice of the inspection industry.
2.0 PURPOSE and SCOPE
- 2.1 The inspector SHALL:
A. Observe installed systems and
components listed in these Standards.
B. Submit a written report to the
client which shall:
- 1. Identify certain components
specified in these Standards.
- 2. State the observed general condition
of the readily accessible items listed within these Standards:
- (Statements of condition shall note any
observed situation which is likely to affect the function or operation of a
system or component.)
- 3. Any installed systems or components
specified in these Standards which were not observed and state why they were
not observed.
- 4. Positively identify any observed
potential or imminent hazard.
- 5. Include the inspection of detached
buildings located on the property when the detached building is listed as
part of the property to be inspected, and the inspection is requested by the
client.
- 2.2 These Standards are NOT intended
to limit the inspector from:
A. Reporting observations and
conditions in addition to those required in Section 2.1
B. Providing any additional inspection
services.
C. Excluding various installed systems
or components and any other services from the inspection if requested by the
client.
3.0 GENERAL LIMITATIONS and
EXCLUSIONS
- 3.1 General limitations:
A. Inspections performed in accordance
with these Standards are visual and are NOT technically exhaustive.
- 3.2 General exclusions:
A. The inspector will NOT report
on:
- 1. The causes of any situation which
may adversely affect the function or operation of a system or component and
indicates the need for correction.
- 2. The suitability of the property for
any specialized use.
- 3. Compliance or non-compliance with
governing codes, ordinances restrictive covenants, and statutes including,
but not limited to local building codes, zoning and land use.
- 4. The market value of the property or
its market-ability.
- 5. The advisability or inadvisability
of purchase of the property.
- 6. Any component or system which was
not observed, except to report that it was not observed.
- 7. Any item(s) which are concealed or
not readily accessible.
3.2 B. The inspector will NOT:
- 1. Offer or perform any act or service
contrary to law.
- 2. Offer or perform engineering or
architectural services.
- 3. Calculate the strength, adequacy, or
efficiency of any system or component.
- 4. Enter any area or perform any
procedure which may damage the property or its components or be dangerous to
the inspector or other persons.
- 5. Operate any system or component
which is shut down or otherwise inoperable.
- 6. Operate any system or component
which does not respond to normal operating controls.
- 7. Move personal items,
furniture,equipment, plant life, soil, snow, ice, or debris which obstructs
access or visibility.
- 8. Remove access panels and covers
which are not readily detachable without tools, except electrical main,
distribution, and sub-panels.
- 9. Will not make any determination
about damage caused to the structure or any systems by termites and/or any
other insects, or organisms, if contradictory to state law. However, any
findings which tend to indicate that termites or other insects may have
infested the inspected property shall be described.
- (Inspectors [who are not licensed pest
inspectors] shall comply with any and all State regulations that may apply
to Pest Reports.)
- 10. Determine the presence or absence
of any suspected hazardous substance including but not limited to: Toxins,
carcinogens, noise, contaminants in soil, water and air.
- Limitations and exclusions specific to
individual systems are listed in the following sections.
4.0 SYSTEM: STRUCTURAL COMPONENTS
- 4.1 The inspector SHALL observe
and report on:
A. Structural components including:
- 1. Foundations
- 2. Floors
- 3. Walls
- 4. Ceilings
- 5. Stairs
- 6. Roofs
B. Sumps, sump pumps, and related
equipment.
- 4.2 The inspector SHALL:
A. Identify the type of:
- 1. Foundation
- 2. Floor structure
- 3. Wall structure
- 4. Roof structure
B. Probe structural components where
deterioration is suspected. However, probing is NOT required when
probing would damage any finished surface.
C. Enter under-floor crawl spaces and
attic spaces except when access is obstructed; when headroom is less that 18
inches in crawl spaces or 36 inches in attic spaces; when entry could damage
the property; or when dangerous or adverse situations are suspected.
D. Report the methods used to observe
underfloor crawl spaces and attics when these areas are not entered or when
access or visibility is limited.
5.0 SYSTEM: EXTERIOR
- 5.1 The inspector SHALL observe
and report on:
A. Exterior wall coverings, flashings and trim
B. Primary windows and doors
C. Garage-door operators.
D. Decks, balconies, stoops steps, areaways,
and porches including railings.
E. Eaves, soffits, and fascias.
F. Vegetation, grading, drainage, driveways,
patios, walkways and retaining walls with respect to their effect on the
condition of the building.
- 5.2 The inspector SHALL:
A. Identify exterior wall covering materials.
B. Operate all exterior doors including garage
doors, manually or by using permanently installed controls of any garage
door operator.
C. Report whether or not any garage door
operator will automatically reverse when meeting reasonable resistance
during closing.
- 5.3 The inspector is NOT
required to report on:
A. Garage door operator remote control
transmitters
B. Geological conditions
C. Soil conditions
D. Recreational facilities
E. Foundation drainage systems
F. Outbuildings other than garages and
carports
6.0 SYSTEM: ROOFING
- 6.1 The inspector SHALL observe
the roof to determine it's approximate remaining life and report on:
A. Roof coverings
B. Roof drainage systems
C. Flashings
D. Skylights, chimneys and roof penetrations.
E. Signs of leaks or abnormal condensation on
building components.
- 6.2 The inspector SHALL:
A. Identify the type of roof covering
materials
B. Report the methods used to observe the
roofing.
- 6.3 The inspector is NOT
required to:
A. Walk on the roofing when walking could
damage the property or be unsafe to the inspector.
7.0 SYSTEM: PLUMBING
- 7.1 The inspector SHALL observe
and report on
A. Interior water distribution system
including:
- 1. Water supply and distribution piping
materials.
- 2. Fixtures and faucets
- 3. Functional flow
- 4. Leaks
- 5. Cross connections
B. Interior drain, waste and vent system
including:
- 1. Traps, drains waste, and vent piping, and
piping supports.
- 2. Leaks
- 3. Functional drainage
C. Hot water systems including:
- 1. Water heating equipment
- 2. Normal operating controls
- 3. Automatic safety controls
- 4. Combustion air and venting
- 5. Clearance to combustibles
D. Fuel storage and distribution of systems
including:
- 1. Interior fuel storage equipment, supply
piping, venting, and supports.
- 2. Leaks
- 7.2 The inspector SHALL:
A. Identify:
- 1. Water supply and distribution piping
materials
- 2. Drain, waste, and vent piping materials
- 3. Water heating equipment.
B. Operate all plumbing fixtures and faucets
where the faucets are not connected to a household appliance, (except
sprinkler systems and hose bibs).
- 7.3 The inspector is NOT
required to:
A. State the effectiveness of anti-siphon
devises
B. Determine whether water supply and waste
disposal systems are public or private.
C. Operate Automatic safety controls.
D. Operate any valve except water closet flush
valves and fixture faucets.
E. Report on:
- 1. Water conditioning systems
- 2. Fire and lawn sprinkler systems
- 3. On-site water supply quality and quantity
- 4. On-site waste disposal systems
- 5. Foundation irrigation systems
- 6. Spas, except as to functional flow and
functional drainage
- 7. Pools
8.0 SYSTEM: ELECTRICAL
- 8.1 The inspector SHALL observe
and report on:
A. Service entrance conductors condition.
B. Service equipment, grounding equipment,
main over-current device, main and distribution panels.
C. Amperage and voltage ratings of the
service.
D. Branch circuit conductors, their
over-current devices, and the compatibility of their amp capacities and
voltages.
E. The operation of a representative number of
installed lighting fixture, switches and receptacles located inside the
house and garage, and on its exterior walls.
F. The polarity and grounding of all
receptacles within six feet of interior plumbing fixtures, and all
accessible receptacles in the garage and attached to the exterior.
G. The operation of Ground Fault Circuit
Interrupters (GFI).
- 8.2 The inspector SHALL:
A. Identify:
- 1. Service amperage and voltage
- 2. Service entry conductor condition, if
visible
- 3. Service type as being overhead or
underground
- 4. Location of main and distribution panels.
B. Report any observed aluminum branch circuit
wiring.
- 8.3 The inspector is NOT
required to:
A. Insert any tool, probe or testing device
inside the panels.
B. Test or operate any over-current device
except Ground Fault Circuit Interrupters.
C. Dismantle any electrical device or control
other than to remove the covers of the main and auxiliary distribution
panels.
D. Observe or report on:
- 1. Low voltage systems
- 2. Alarm systems
- 3. Intercom systems
9.0 SYSTEM: HEATING
- 9.1 The inspector SHALL observe
and report on:
A. Permanently installed heating systems
including:
- 1. Heating equipment
- 2. Normal operating controls
- 3. Automatic safety controls
- 4. Exteriors of chimneys, flues, and vents
- 5. Combustion air supply
- 6. Solid fuel heating devices
- 7. Clearance to combustibles
- 8. Heat distribution systems including
blowers, pumps, ducts, piping, radiators, convectors, registers, air
filters.
- 9. The presence of an installed heat source in
each room.
-
- 9.2
The inspector SHALL:
A. Identify:
- 1. Energy source
- 2. Heating equipment and distribution type
B. Operate the system(s) using normal
operating controls.
C. Open readily openable access panels
provided by the manufacturer or installer for routine homeowner maintenance.
- 9.3 The inspector is NOT
required to:
A. Operate heating systems when weather
conditions or other circumstances may cause equipment damage.
B. Operate Automatic safety controls
C. Ignite or extinguish solid fuel fires.
D. Report on:
- 1. The interior of flues or combustion
chambers
- 2. Fireplace insert flue connections
- 3. Humidifiers
- 4. Electronic air filters
- 5. The uniformity or adequacy of heat supply
to the various rooms.
10.0 SYSTEM: CENTRAL AIR
CONDITIONING
- 10.1 The inspector SHALL observe
and report on:
A. Central air conditioning including:
- 1. Cooling and air handling equipment
- 2. Normal operating controls
B. Distribution systems including:
- 1. Ducts, registers, and air filters
- 2. The presence of an installed cooling source
in each room
-
- 10.2
The inspector SHALL:
A. Identify:
- 1. Energy sources
- 2. Cooling equipment type
B. Operate the systems using normal operating
controls.
C. Open readily openable access panels
provided by the manufacturer or installer for routine homeowner maintenance.
- 10.3 The inspector is NOT
required to:
A. Operate cooling systems when weather
conditions or other circumstances may cause equipment damage
B. Observe or report on non-central air
conditioners
C. Report on the uniformity or adequacy of
cold air supply to the various rooms
11.0 SYSTEM: INTERIORS
- 11.1 The inspector SHALL observe
and report on:
A. Wall, ceiling, and floor surfaces
B. Steps, stairways, balconies, and railings
C. Cabinets and counters
D. Windows, and doors including hardware
E. Fire resistant separation walls, ceilings,
and doors between a dwelling unit and an attached garage.
- 11.2 The inspector SHALL:
A. Identify window types
B. Operate all accessible primary windows and
interior doors
- 11.3 The inspector is NOT
required to report on:
A. Finishes on the interior walls, ceilings,
and floors
B. Carpeting
C. Draperies, blinds, or other window
treatments
D. Household appliances
E. Recreational facilities
12.0 SYSTEM: INSULATION AND
VENTILATION
- 12.1 The inspector SHALL observe
and report on:
A. Insulation of unfinished attic and
foundation areas
B. Ventilation of attics and foundation areas
C. Kitchen, bath, and laundry venting systems.
- 12.2 The inspector SHALL
identify:
A. Observe insulation in unfinished attics
B. Observe insulation in under-floor crawl
spaces
- 12.3 The inspector is NOT
required to report on:
A. Insulation and vapor retarders concealed in
ceilings or exterior walls.
B. Venting equipment which is integral with
household appliances.
Glossary of Terms
Automatic (System) Safety Controls:
Devices designed and installed to protect systems and components from
excessively high or low pressures and temperatures, excessive electrical
current, loss of water, loss of ignition, fuel leaks, fire, freezing, or
other unsafe conditions.
Central Air Conditioning: A system
which uses ducts to distribute cooled and/or dehumidified air to more than
one room at a time, and which is not plugged into an electrical convenience
outlet.
Clearance to Combustibles: The distance
between a heat producing appliance, chimney, chimney connector, vent, vent
connector, or plenum and other surfaces. Also, in garages, the distance
between the floor and an installed source of ignition.
Cross Connections: Any physical
connection or arrangement between potable water and any source of
contamination.
Dangerous or Adverse situations:
Situations which pose a threat of injury to the inspector, and those
situations which require use of special protective clothing or safety
equipment.
Dismantle: To take apart or remove any
component, device or piece of equipment that is bolted, screwed, (or
fastened by other means), that would not be removed by a homeowner in the
course of normal household maintenance.
Engineering: Analysis or design work
requiring extensive preparation and experience in the use of mathematics,
chemistry, physics, and the engineering sciences.
Functional Drainage: A drain is
functional when it empties in a reasonable amount of time and does not
overflow when another fixture is drained simultaneously.
Functional Flow: A reasonable flow at
the highest fixture in a dwelling when another fixture is operated
simultaneously.
Household Appliances: Kitchen, laundry,
and similar appliances are not included in these Standards since a visual
inspection may not indicate the effectiveness of their operation.
Identify: Report in writing a system or
component by its type, or other observed characteristics, to distinguish it
from other systems or components used for the same purpose.
Inspector: Any person who examines any
component of a building, through visual means and through normal user
controls, without the use of mathematical sciences.
Installed: Attached (connected) to the
structural, mechanical, plumbing or electrical system of the house such that
the item installed cannot be removed without the use of tools.
Normal Operating Controls: Homeowner
operated devices such as a thermostat, wall switch or safety switch.
Observe: The act of making a visual
examination.
Operate: To cause systems or equipment
to function.
Primary Windows and Doors: Windows and
exterior doors which are designed to remain in their respective openings
year round.
Readily Openable Access Panel: A panel
provided for homeowner inspection and maintenance which has removable or
operable fasteners or latch devices in order to be lifted off, swung open,
or otherwise removed by one person (without the use of tools) and its edges
and fasteners are not painted in place. Limited to those panels within
normal reach or from a 4-foot stepladder, and which are not blocked by
stored items, furniture, or building components.
Recreational Facilities: Spas, saunas,
steam baths, swimming pools, tennis courts, playground equipment, and other
exercise entertainment, or athletic equipment.
Representative Number: For multiple
identical components such as windows and electric outlets - one such
component per room. For multiple identical exterior components - one such
component on each side of the building.
Roof Drainage Systems: Gutters,
downspouts, leaders, splashblocks, and similar components used to carry
water off a roof and away from a building.
Shut Down: A piece of equipment or
system is shut down when it cannot be operated by the device or control
which a homeowner would use to normally operate. IF the safety switch, fuse,
or circuit breaker is in the "off" position the Inspector is NOT
required to operate the equipment or system.
Solid Fuel Heating Device: Any wood,
coal, or other similar organic fuel burning device, including but not
limited to fireplaces whether masonry or factory built, fireplace inserts
and stoves, wood stoves (room heaters), central furnaces, and combinations
of these devices.
Structural Component: A building
component which supports interior or exterior finish materials or other
building components.
Technically Exhaustive: An inspection
is technically exhaustive when it involves the extensive use of
measurements, instruments, testing, calculations, and other means to develop
scientific or engineering findings, conclusions, and recommendations.
Under-floor Crawl Space: The area
within the confines of the foundation and between the ground and the
underside of the lowest floor structural component.
Water Supply Quality: Water quality is
based on the bacterial, chemical, mineral and solids
content of the water.
|